8 program sequences, 36 programs, Di potentiation
Art. No. G16E26
What it adds
Expert Module 1 is an expert-level extension for the 2nd generation BICOM optima®. It brings three independent additions to the device in one licence.
New basic program sequences. Five sequences, 10500 to 10504, selected by the patient’s conductance value, plus a sequence for therapy mode A that needs no conductance reading. These are the successors to the 10250 series, rebuilt for the 250 Hz bandpass of the current device with an 8 second cycle time.
Revised pathogen and stabilisation sequences. The established sequences 10325, 10326 and 10327 have been reworked as 10505, 10506 and 10507. The frequency cycle moves from 3 seconds to 8 seconds, so every frequency and every amplification step inside the bandpass is covered within the therapy time.
New indication-specific programs, 3520 to 3555. REGUMED describe them as 34 new programs; their published list runs to 36 numbers and every one is included. Orthopaedics, teeth and jaw, lung, pain, the vegetative system, tumour aftercare, nutrient points, detoxification, neurology and more. All appear under their own category on the device, with the applicator setup and cup fitting shown on screen.
Alongside those three parts, therapy mode Di is added to the analogue potentiation menu. With H + Di, Ai and A already there, every BICOM® therapy mode is now available for analogue potentiation from D3 to D1000.
Where it comes from
The programs were developed by Marcel Riffel, BICOM® therapist and AKI speaker from Ostfildern, working with REGUMED. His 2014 work on basic programs started from a simple observation: the ADEY window is already accounted for in BICOM® therapy, but each patient still has an individual bandpass frequency and amplification level at which the organism is most accessible. Finding that by hand is slow, so the basic programs sweep through amplification and bandpass frequency to reach it automatically.
Later work with REGUMED showed that not every frequency responds to every amplification level, which is what the 10250 series addressed. When the bandpass on the latest optima was widened to 250 Hz, the sweep needed a longer cycle to cover it. Expert Module 1 is that next step: the same approach, rebuilt for the current hardware. The indication programs were developed on an empirical basis and have been used extensively in practice.
Basic program sequences
Found on the device under Basic Programs, Other basic programs. Select the sequence by conductance value, or use 10504 when you prefer not to test it.
| Sequence | Program no. | Mode | Time |
|---|---|---|---|
| Sequence 10503 Basic program H + Di. Normal energetic state, conductance value 80 to 89 |
|||
| 1st program: Basic program H + Di LDF BP | 3506 | H + Di | 10 min |
| 2nd program: Basic program H + Di BP | 3507 | H + Di | 14 min |
| Sequence 10500 Basic program Ai. Yang state, conductance value 90 to 100 |
|||
| 1st program: Basic program Ai LDF BP | 3500 | Ai | 10 min |
| 2nd program: Basic program Ai BP | 3501 | Ai | 14 min |
| Sequence 10501 Basic program Di. Yin state, conductance value 72 to 79 |
|||
| 1st program: Basic program Di LDF BP | 3502 | Di | 10 min |
| 2nd program: Basic program Di BP | 3503 | Di | 14 min |
| Sequence 10502 Basic program H. Exhausted patient, conductance value under 72 |
|||
| 1st program: Basic program H LDF BP | 3504 | H | 10 min |
| 2nd program: Basic program H BP | 3505 | H | 14 min |
| Sequence 10504 Basic program A. Without conductance value testing |
|||
| 1st program: Basic program A LDF BP | 3508 | A | 10 min |
| 2nd program: Basic program A BP | 3509 | A | 14 min |
Pathogen and stabilisation sequences
Found under Program sequences, Allergies. Test the substance for Ai or Di first with your usual bioenergetic method (biotensor, kinesiology or EAV), place it in the input cup of channel 1 and set the matching sequence. The patient sits only at the output. The instructions for use include a step-by-step biotensor test using program 998, and REGUMED ask that you never change the time or amplification on these sequences.
| Sequence | Program no. | Mode | Time |
|---|---|---|---|
| Sequence 10505 Pathogens Ai |
|||
| 1st program: low deep frequency with bandpass | 3510 | Ai | 10 min |
| 2nd program: normal frequency range with bandpass | 3511 | Ai | 14 min |
| 3rd program: without bandpass | 3512 | Ai | 15 min |
| Sequence 10506 Pathogens Di |
|||
| 1st program: low deep frequency with bandpass | 3513 | Di | 10 min |
| 2nd program: normal frequency range with bandpass | 3514 | Di | 14 min |
| 3rd program: without bandpass | 3515 | Di | 15 min |
| Sequence 10507 Stabilization A |
|||
| 1st program: low deep frequency with bandpass | 3516 | A | 10 min |
| 2nd program: normal frequency range with bandpass | 3517 | A | 14 min |
| 3rd program: without bandpass | 3518 | A | 15 min |
The new indication-specific programs
Each program appears in its own category on the device. Names are reproduced as REGUMED publish them, so they match what you see on screen.
| Program no. | Program |
|---|---|
| Joints and orthopaedics | |
| 3520.0 | Stabilize ligament structures |
| 3527.0 | Bone pain, post-traumatic |
| 3531.0 | Bone pain, post-traumatic |
| 3538.0 | Bone pain, post-traumatic |
| 3539.0 | Painful soft tissue (2nd recommendation) |
| 3553.0 | Post-operative treatment of the hip after synovectomy |
| Vegetative system | |
| 3521.0 | Nightmares 1 (supportive) |
| 3522.0 | Nightmares 2 (supportive) |
| 3528.0 | Improving quality of life / emotional dyspnea |
| Tumour aftercare | |
| 3526.0 | Supportive therapy mammary CA |
| 3551.0 | Activation red bone marrow for leukopoiesis |
| Lung | |
| 3529.0 | Breathing restriction, thoracic tightness |
| 3530.0 | Shortness of breath |
| Nutrient point programs | |
| 3532.0 | Nutrient point for titanium |
| 3540.0 | Nutrient point for silver |
| 3541.0 | 2nd nutrient entry for vitamin Q10 |
| 3542.0 | Nutrient point for thallium |
| 3543.0 | Nutrient point for platinum |
| 3545.0 | Nutrient point for tin |
| 3546.0 | Nutrient point for palladium |
| Pain | |
| 3533.0 | Post-operative pain, head (after aneurysm surgery) |
| 3534.0 | Painful soft tissue |
| Teeth and jaw | |
| 3535.0 | Acute pulpitis |
| 3536.0 | Radicular cyst |
| 3544.0 | Diaphragma oris (correction temporomandibular joint) |
| 3547.0 | Tooth root granuloma 2 |
| 3549.0 | Odontogenic fundus abscess |
| Spleen and pancreas | |
| 3537.0 | Pancreatic insufficiency exocrine (supporting) |
| Blockages | |
| 3548.0 | Release emotional blockage |
| Detoxification programs | |
| 3552.0 | Detoxification of the mucous membranes |
| Neurology | |
| 3554.0 | Optimize cerebrospinal fluid circulation |
| Other programs (search by program number) | |
| 3523.0 | Coronavirus exposure 1st recommendation |
| 3524.0 | Cytomegalovirus exposure |
| 3525.0 | Coronavirus exposure 2nd recommendation |
| 3550.0 | Psorinum Erbtoxin exposure |
| 3555.0 | Tuberculinum hereditary toxin exposure |
Di in the potentiation menu
Menu section 8 now offers 13 potentising programs in therapy mode Di, from D3 to D1000, matching the levels already available for the other modes. REGUMED’s guidance pairs H + Di with food and the body’s own secretions, Ai with potential pathogens, A with stabilising substances, and Di with the body’s own secretions and pathogens. Test the mode with program 998, step through the potencies with the foot switch, and combine several positive potencies into a sequence for a potency chord. The information is stored on a carrier (chip, drops or oil) and the treatment is repeated every four weeks.
| Program no. | Program |
|---|---|
| 70.0 | Potentising program Di, D3 |
| 71.0 | Potentising program Di, D5 |
| 72.0 | Potentising program Di, D6 |
| 73.0 | Potentising program Di, D8 |
| 74.0 | Potentising program Di, D10 |
| 75.0 | Potentising program Di, D12 |
| 76.0 | Potentising program Di, D15 |
| 77.0 | Potentising program Di, D30 |
| 78.0 | Potentising program Di, D60 |
| 79.0 | Potentising program Di, D100 |
| 80.0 | Potentising program Di, D200 |
| 81.0 | Potentising program Di, D400 |
| 82.0 | Potentising program Di, D1000 |
Installation
Everything arrives on one USB stick from REGUMED, keyed to your device serial number: the Expert Module 1 licence, the device software update (8.0.12) if your device needs it, and the BICOMmultisoft® pilot 2.11 update for pilot users. Installation of the module itself takes about 10 minutes. With the device off, insert the stick into the USB-IPC port, connect the power supply and switch on; the device enters update mode on its own and installs the licence with no input from you. Afterwards the version screen lists EM1 under REGLIC to confirm the module is active. Full installation instructions are included.
Program and sequence names on this page are REGUMED’s own labels, reproduced so they match the device display. Expert Module 1 is a practitioner product for use with a BICOM optima® in line with the manufacturer’s instructions for use.
Compatibility
For BICOM optima® devices of the 2nd generation, the touch screen models V7 and V8, including the BICOM optima® mobile (B32, B34 and BM34, Basic and Complete versions). Not for 1st generation V5 and V6 devices, which take the Optima extension modules I and II instead.
If you are not sure which generation your BICOM optima® is, press 9 for settings then 0 for version, and read the version number under “update”.




Reviews